Baumer GNAMG Manuel d'utilisateur Page 6

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 19
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 5
Manual_GNAMG_Profibus_EN.doc 6/19 Baumer IVO GmbH & Co. KG
04.05.11 Villingen-Schwenningen, Germany
4. Operating parameters of the inclination sensor
Explanations on operating parameters
Parameter Significance
Resolution Resolution of the inclination angle
0.001° = 0001h (not possible for the 360° sensor)
0.01° = 000Ah (not possible for the 360° sensor)
0.1° = 0064h
1.0° = 03E8h
Preset value X-axis
(Slope lateral
preset value)
The actual inclination value of the X-axis is set to a requested value
Preset value Y-axis
(Slope long preset
value)
The actual inclination value of the Y-axis is set to a requested value
(not possible for the 360° sensor))
Offset X-axis
(Slope lateral
offset)
The here entered value is directly added to the actual inclination value of the X-
axis (not possible for the 360° sensor)
Offset-value
(Slope long offset)
The here entered value is directly added to the actual inclination value of the Y-
axis (not possible for the 360° sensor)