N 214
12 www.baumer.com
When the error message is returned, the two positions "line" und "mode" are dropped
Detailed error description:
Error 1 : Format error(<ETX> is not positioned correctly). This error occurs
e.g. if the data format is not observed during the programming(e.g.:
when programming the start value, only 5 data positions are
transmitted instead of 6)
Error 2 : Line(position) does not exist or separation line
Error 3 : Parameter error(invalid values in the protocol). That
means, for example, that the scaling factor does not only consist
of numerals but also of other invalid signs or that a given value
is not within a permissible range.
6. List of the control characters used
Control character Hex Decimal
<STX> 02 02
<ETX> 03 03
<ACK> 06 06
<LF> 0A 10
<CR> 0D 13
<DC1> 11 17
<CAN> 18 24
<DEL> 7F 127
7. Operating scheme
Line Factory setting Customer program Brief description
01 0 XP – Counter count main counter
20 - - - - - - Separation line
21 2 1 S F 2 1 Start value
1.0 0 0 0
23 2 3 S F 2 3 Scaling factor
1.0 0 0 0
24 2 4 0 2 4 Decimal point
25 2 5 0 2 5 Counting mode
26 2 6 0 2 6 Frequency main counter track A
27 2 7 0 2 7 Frequency main counter track B
28 2 8 0 2 8 Input logic
29 2 9 0 2 9 Reset main counter
30 3 0 0 3 0 Reset key function enable on operating level
31 3 1 0 3 1 Function signal input 9
32 3 2 0 3 2 Output contact assignment
33 3 3 0 3 3 Output logic for digital output
34 3 4 0 3 4 Output contact function
35 3 5 t 1 3 5 Impulse signal time P1
0.2 5
40 4 0 C o d 4 0 Code
0
51 5 1 0 5 1 Baud rate
52 5 2 0 5 2 Parity
53 5 3 0 5 3 Stop bits
54 5 4 0 5 4 Address
67 - - - - - - Separation line