8. Programming scheme
Lines 11-16 Status for line 1-6
0 Parameter can be changed
1 Deletion or input disabled
2 Parameter is skipped
Line 21 Start value
0
Default
-999999 Min.
999999 Max.
Line 22 Operating modes
0 Progressive preselection
1 Principal preselection
2 Parallel comparison
3 Trailing preselection P1
Line 23 Scaling factor
1.0000 Default
00.0001 Min.
9999.99 Max.
Line 24 Decimal point
0 No decimal point
1 00000.0
2 0000.00
3 000.000
4 00.0000
Line 25 Counting mode
0 Track A if necessary UP/DOWN signal
on track B
1 Difference count (A-B)
2 Sum count (A+B)
3 Track A 90° B Single analysis
4 Track A 90° B Double analysis
5 Track A 90° B Fourfold analysis
Line 26 Frequency main counter track A
0 10 kHz
1 25 Hz
2 3 Hz
Line 27 Frequency main counter track B
0 10 kHz
1 25 Hz
2 3 Hz
Line 28 Input logic
0 PNP – switching threshold 11V
1
NPN – switching threshold 11V
2
PNP – switching threshold 5V
3
NPN – switching threshold 5V
4
PNP – switching threshold 2,5V
5
NPN – switching threshold 2,5V
Line 29 Reset main counter
0 Autom. reset and ext. static
1 Autom. reset und ext. diff.
2 Ext. static
3 Ext. differentiated
Line 30 Reset key function enable
0 Reset key enabled
1 Reset key disabled
Line 31 Function signal input 9
0 Stop
1 Hold
2 Keylock
3 Time meter on/off
4 Print
Line 32 Output contact assignment
0 In case of 0 contact
1 In case of start value
Line 33 Output logic for digital outputs
0 Both outputs as make contacts
1 P1 break contact, P2 make contact
2 P1 make contact, P2 break contact
3 Both outputs as break contacts