NE134
14 www.baumer.com
41
0.2 5
4 1
Output time P1
42
0.2 5
4 2
Output time P2
50
0 0 0 0
5 0
Code setting
51
0
5 1
Baudrate
52
0
5 2
Parity
53
0
5 3
Stop bits
54
0 0
5 4
Address
55
- - - - - -
Separating line
9. Programming Plan
Lines 11-17 Status of lines 1-7
0 Parameter alteration accessed
1 Clear resp. input lock
2 Skip parameter
Line 21 Operation Modes Main counter
0 * Add. – Reset to SC, Stop contact P2
1 Sub. - Autoreset at SC, Stop contact at SC
2 Sub. - Autoreset at 0, Stop contact at SC
Line 22 Preset Mode
0 * Main counter 2 presets (step presets)
1 Main counter 2 Presets (P1 = trailing
preset)
2 Main counter with preset P2, batch with P1
Line 23 Kinds of Reset
0 * Main counter and batch counter with
autoreset
1 Main counter w/o,batch counter with
autoreset
2 Main counter with,batch counter w/o
autoreset
3 Main counter and batch counter w/o autoreset
Line 24 Decimal Point for PC, (P1,) P2, SC and tot
0 * No decimal point
1 00000.0
2 0000.00
3 000.000
Line 26 Measuring unit displayed
0 * No measuring unit
1 m
2 dm
3 cm
4 mm
5 L
Line 27 Lower Dispaly Assignment
0 W/o lower display
1 P1 - Preset value
2 * P2 - Preset value
3 SC - start count
4 tot – totalizer
5 b - batch counter
6 SF - scaling factor
Line 30 Counting Mode
0 * Count track A / direction inversion track B
1 Difference (A-B)
2 Total (A+B)
3 Track A 90° B single evaluation
4 Track A 90° B double evaluation
5 Track A 90° B fourfold evaluation
Line 31 Frequency Main counter track A
0 * 10 kHz
1 25 Hz
2 3 Hz
Line 32 Frequency Main counter track B
0 * 10 kHz
1 25 Hz
2 3 Hz